Visible spectrum of stable sonoluminescence

Loading...
Thumbnail Image
Authors
Carlson, Joseph T.
Subjects
Sonoluminescence spectrum
Advisors
Maruyama, Xavier K.
Atchley, Anthony A.
Date of Issue
1992-12
Date
December 1992
Publisher
Monterey, California. Naval Postgraduate School
Language
en_US
Abstract
Synchronous emissions of picosecond pulses of light are observed to originate from a bubble trapped at the pressure antinode of a resonant sound field. The spectrum has been measured using a single slit spectrometer equipped with a linear array CCD detector. Spectra from differing solutions of water and glycerin are compared to the visible blackbody spectrum distribution. Assuming a blackbody model, apparent temperatures of 18,900 Kelvins are observed in pure water. Increasing glycerin concentration appears to correlate with cooler blackbody temperatures. The spectrum is also found to continually change with time, independent of input parameters.