Fiber optic accelerometers and seismometers
Loading...
Authors
Brown, D.A.
Subjects
Advisors
Date of Issue
1996-04-01
Date
Publisher
Language
Abstract
This paper presents performance and figures-of-merit of fiber optic interferometric accelerometers and seismometers using flexural disk, mandrel, and fluid filled transducers. Flexural disk devices having sensitivities of 50 radians/g and operating bandwidths to 2 kHz have been reported. This sensitivity corresponds to a minimum detectable signal of 20 nano-g/{radical}Hz for a system demodulation noise floor of 1 micro-radian/{radical}Hz. {copyright} {ital 1996 American Institute of Physics.}
Type
Article
Description
The article of record as published may be found at https://doi.org/10.1063/1.50341
Series/Report No
Department
Organization
Identifiers
NPS Report Number
Sponsors
Funder
Format
Citation
Journal Name: AIP Conference Proceedings; Journal Volume: 368; Journal Issue: 1; Conference: Acoustic velocity sensor focused workshop, Mystic, CT (United States), 12-13 Sep 1995; Other Information: PBD: Apr 1996
Distribution Statement
Rights