Capture coefficients of nitrogen on a cryogenically cooled panel
Loading...
Authors
Bevan, John Albert
Subjects
Capture coefficient
Nitrogen gas
Cryopumping
High vacuum
Nitrogen gas
Cryopumping
High vacuum
Advisors
Pucci, Paul F.
Date of Issue
1967-06
Date
June 1967
Publisher
Language
en_US
Abstract
The pressure drop method was used to experimentally determine the capture coefficients of nitrogen gas on a flat cryopanel maintained at a temperature of 25°K. The capture coefficients for 300°K nitrogen varied from a maximum of 0.70 for low system gas loads to a minimum of 0.10 for high system gas loads.