An energy analysis of the pseudo Wigner-Ville distribution in support of machinery monitoring and diagnostics

Authors
Spooner, Scott G.
Advisors
Shin, Young S.
Second Readers
Subjects
Machinery monitoring
Transient
Pseudo Wigner-Ville Distribution
Machinery diagnostics
Date of Issue
1992-06
Date
June 1992
Publisher
Monterey, California. Naval Postgraduate School
Language
en_US
Abstract
The Pseudo Wigner-Ville Distribution is a signal transformation of an input time signal into a joint time-frequency domain, that provides an excellent characterization of an input signal as well as its respective energy content. A smoothing window and energy sensitivity analysis of the discretized Pseudo Wigner-Ville Distribution is presented along with a machinery monitoring application using the resulting Wigner-Ville energy of the sampled signal. The ability to apply the Pseudo Wigner-Ville Distribution to both steady-state and transient machinery may enable the monitoring and diagnostics of virtually any piece of equipment.
Type
Thesis
Description
Series/Report No
Department
Mechanical Engineering
Organization
Naval Postgraduate School (U.S.)
Identifiers
NPS Report Number
Sponsors
Funding
Format
88 p.
Citation
Distribution Statement
Approved for public release; distribution is unlimited.
Rights
This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
Collections