Comparison of calculations and measurements of the off-axis radiation dose (Si) in liquid nitrogen as a function of radiation length

Loading...
Thumbnail Image
Authors
Cromar, Patrick F.
Subjects
Air Dose
Off-axis dose
Off- axis radiation
Bremsstrahlung
Advisors
Buskirk, Fred R.
Date of Issue
1984-12-01
Date
December 1984
Publisher
Monterey, CA; Naval Postgraduate School
Language
en_US
Abstract
In this thesis results are presented from a study of the off-axis X and Gamma radiation field caused by a highly relativistic electron beam in liquid Nitrogen at various path lengths out to 2 radiation lengths. The off-axis dose in Silicon was calculated using electron/photon transport code CYLTRAN and measured using thermal luminescent dosimeters (TLD's). Calculations were performed on a CDC-7600 computer ar Los Alamos National Laboratory and measurements were made using the Naval Postgraduate School 100 Mev Linac. Comparison of the results is made and CYLTRAN is found to be in agreement with experimentally measured values. The CYLTRAN results are extended to the off-axis dose caused by a 100 Mev electron beam in air at Standard Temperature and Pressure (STP)
Type
Thesis
Description
Series/Report No
Department
Department of Physics
Organization
Naval Postgraduate School (U.S.)
Identifiers
NPS Report Number
Sponsors
Funder
Format
Citation
Distribution Statement
Approved for public release; distribution is unlimited.
Rights
This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.