dc.description.abstractThe heat transfer and pressure drop characteristics of water flowing in a vertical annulus under counter flow conditions were investigated. The heat exchanger used consisted of a straight tube in tube test section with water as the heat transfer medium in both tubes „ Convection coefficients of heat transfer between the inner tube and the fluid flowing in the annulus were determined from the measured inner tube wall and average fluid bulk temperature and the energy transferred to the water flowing in the annulus.en_US