Probe measurements on the P-4 system in single cathode operation.
Abstract
In this report the plasma of the P-4 system in single-cathode operation is examined by probe techniques and compared with data taken previously in two-cathode operation. Although no radical differences were discovered, the data as summarized in Tables 1 and 2 and Figs. 7 through 12 confirms the visual observation that the plasma column is more sharply defined in single-cathode operation.
Description
UCRL-5998; Controlled thermonuclear processes, UC-20
Collections
Related items
Showing items related by title, author, creator and subject.
-
Engineered Electrodes for Safer Rechargeable Batteries
Pol, Vilas (2017-08-11);Dr. Vilas Pol, Associate Professor of Chemical Engineering, Purdue University -
Solid-state spark chamber for detection of radiation
Karunasiri, Gamani; Alves, Fabio Durante Pereira (The United States of America as represented by the Secretary of the Navy, Washington, DC (US), 2017-03-14);A combined semiconductor controlled circuit (CSCC) includes a semiconductor controlled switch (SCS). The SCS includes anode, cathode, anode gate and cathode gate terminals connected to P₁ anode, N₂ cathode, N₁ anode ... -