Condensation heat transfer of steam on a single horizontal tube
Loading...
Authors
Graber, Kenneth A.
Subjects
Heat transfer
Condensation
Experimental apparatus
Enhanced condensation
Condensation
Experimental apparatus
Enhanced condensation
Advisors
Marto, P.J.
Date of Issue
1983-06
Date
June 1983
Publisher
Monterey, California. Naval Postgraduate School
Language
en_US
Abstract
An experimental apparatus was designed, constructed and instrumented in an effort to
systematically and carefully study the condensation heat-transfer coefficient on a single, horizontal tube. A smooth, thick-walled copper tube of length 133.5 mm, with an outside diameter of 15.9 mm and an inside diameter of 12.7 mm was instrumented with six wall thermocouples. The temperature rise across the test section was measured accurately using quartz crystal thermometers. The inside heat-transfer coefficient was determined using the Sieder-Tate correlation with leading coefficient of 0.029. Initial steam side data were taken at atmospheric pressure to test the data acquisition/reduction computer programs.
Type
Thesis
Description
Series/Report No
Department
Mechanical Engineering
Organization
Naval Postgraduate School (U.S.)
Identifiers
NPS Report Number
Sponsors
Funder
Format
Citation
Distribution Statement
Approved for public release; distribution is unlimited.
Rights
This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.