Steam condensation heat transfer measurements were made
in a 5-tube test condenser having an additional perforated
tube to simulate up to 30 active tubes. Results were
obtained for smooth tubes and roped tubes wrapped with wire.
A Sieder-Tate equation was used to correlate the inside
heat-transfer coefficient. For smooth tubes, a leading
coefficient of 0.029 was found, while it was 0.061 for the
roped tubes. The average condensing coefficient measured
for 30 smooth tubes was 0.59 times the Nusselt coefficient
calculated for the first tube. When the smooth tubes were
wrapped with wire, this ratio increased up to 0.86.
Further, roped tubes without wire experienced a ratio of
0.63, while roped tubes wrapped with wire resulted in a
ratio of 0.86. These preliminary data show that wire-wrapped
tubes may lead to a significant reduction in
condenser surface area.
Rights
Copyright is reserved by the copyright ownerCollections
Related items
Showing items related by title, author, creator and subject.
-
The effect of condensate inundation on steam condensation heat transfer in a tube bundle
Brower, Steven K. (1985-06);Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped ... -
Filmwise condensation of steam on horizontal wire-wrapped smooth and roped titanium tubes
O'Keefe, Thomas Joseph (Monterey, California. Naval Postgraduate School, 1992-09);Filmwise condensation heat-transfer measurements were performed on horizontal smooth and roped titanium tubes using steam. The roped tubes were a commercially available tube (KORODENSE) with a normal pitch of 7 mm. To ... -
Enhanced condensation of R-113 on a small bundle of horizontal tubes
Mazzone, Robert Walter (Monterey, California. Naval Postgraduate School, 1991-12);Condensation of r-113 was studied using an evaporator condenser test platform. the condenser section contained four horizontal tubes (nominal outer diameter 15.9 mm)forming a vertical in line column with a pitch-to-diameter ...